Autoclave Validation using Ellab Tracksense Pro Dataloggers

13/7/2018

0 Comments

 
In 2011 we started using Veriteq multi channel dataloggers to speed up temperature mapping over standard wired systems. The effect was to significantly reduce temperature mapping times, increase productivity of our engineers and in report quality. In the last two years we have applied that same methodology to autoclaves using Ellab Tracksense Pro dataloggers and the results are staggering.
​
​·       Time savings of 30-60% for autoclave downtime.
·       Data processing and analysis reduced from 3-4 hours to 20 minutes.
·       Review time reduced significantly
·       Removal of subjectivity in data processing
This has been done with a step change in accuracy from ±0.5°C using a thermocouple based system to ±0.05°C whilst complying with EN285. In particular section 6.4.1 on response time, which requires dataloggers to have a T90 of <5s.

For Site Directors and Production Managers this delivers substantial autoclave downtime savings. Using the tracksense pro system removes the need to perform leak rate tests, calibrations and preparing validation loads whilst on the autoclave.

Using Ellab sensors not only reduces the autoclave downtime, but it brings flexibility. Our clients benefit from loads being prepared offline whilst the autoclave is in use, validation runs can then be slotted in around the production requirements. For requalification only, autoclave downtime is the cycle time, for performance qualification loads need to be performed in triplicate but downtime saving is still significant.

For QA reviewers, data and results are clearly displayed with pass/fail criteria. The reports are clear and unambiguous. Data is repeatable and the subjectivity of the test engineers method of calculation removed. The software is validated and 21 CFR Part 11 Compliant.

For Validation Engineers, the system offers bespoke sensor design. We have a large array of sensors to suite challenging load requirements. Sensor insertion into load items is also fully supported by the manufacturer and if we don’t have the right sensor insertion for your requirements Ellab can assist in the design and fabrication of bespoke fittings in their facility.

If you would like more information our engineers are happy to help please call us on 00 44 (0)1833908002 or email Chris Maughan chrism@thermalcompliance.co.uk . We would be happy to visit site and show you how the system can help with Autoclave Validation, Steam In Place, Freeze Drying, Temperature Mapping and Dry Heat Sterilisation. ​
0 Comments

Your comment will be posted after it is approved.


Leave a Reply.

    RSS Feed

    Tweets by @ThermalCom

    Archives

    June 2023
    April 2023
    February 2023
    January 2023
    December 2022
    November 2022
    September 2022
    August 2022
    April 2022
    December 2021
    October 2021
    July 2021
    June 2021
    May 2021
    January 2021
    December 2020
    November 2020
    August 2020
    July 2020
    June 2020
    March 2020
    February 2020
    November 2019
    October 2019
    September 2019
    August 2019
    July 2019
    June 2019
    May 2019
    April 2019
    March 2019
    February 2019
    January 2019
    December 2018
    November 2018
    October 2018
    August 2018
    July 2018
    March 2018
    January 2018
    November 2017
    October 2017
    August 2017
    June 2017
    April 2017
    March 2017
    February 2017
    December 2016
    October 2016
    June 2016
    March 2016
    December 2015
    October 2015
    August 2015
    April 2015
    February 2015
    January 2015
    October 2014
    July 2014
    June 2014
    May 2014
    April 2014
    February 2014
    January 2014
    December 2013
    November 2013
    October 2013
    September 2013
    August 2013
    July 2013
    June 2013

Validation
COMPANY
Home Page
News & Updates
Contact Us

Join Our Mailing List
About Us
Privacy Policy & Terms
OUR SERVICES
Training Courses
Validation Services
Autoclave Validation
​Temperature Mapping

Equipment Rental
​
Remote Validation

Consultancy
​What is temperature Mapping?
Calibration

Thermal Compliance Ltd. Registered in England. Number 6155116. © Copyright Thermal Compliance Limited 2007-2023.
Registered Address: 18 Harelands Courtyard Offices, Moor Road, Richmond, North Yorkshire. DL10 5NY.  VAT Number 915787780
Photo from frankieleon